Our Products

Single Phase Meters

TYPE: EM101

Description

1P Single Phase Energy Meter capable of single total active energy measurement

Voltage  : 1P AC154~264V(L-N) 

Current : AC 10(60)A

Accuracy : KWh Class 1, Kvarh Class 2

Display : Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options : RS485(Modbus RTU)

Single Phase Meters

TYPE: EM102

Description

2P Single Phase Energy Meter capable of single total active energy measurement

Voltage  : 1P AC154~264V(L-N)

Current : AC 10(60)A, 20(100) A

Accuracy : KWh Class 1, Kvarh Class 2

Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options and Features

RS485(Modbus RTU) , Pulse Output, Keypad Programming

Single Phase Meters

TYPE: EM103

Description

Single Phase 2-Wire Energy Meter capable of single total active energy measurement

Voltage : AC154~264V(L-N)

Current : AC 10(60)A, 20(100) A

Accuracy : KWh Class 1

Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options and Features : Multi-Rate/Tarriff, RS485(Modbus RTU), Pulse Output, Keypad Programming

Three Phase Meters

TYPE: EM200

Description

Three Phase Energy Meter with optional direct connection or CT connection

Voltage : AC100~120V or 380~456V (L-L)

Current : AC 1(6) A AC, 10(80) A AC

Accuracy : KWh Class 0.5%

Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options and Features : Auxiliary Function, Multi-Rate/Tarriff, RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic

Three Phase Meters

TYPE: EM201

Description

Three Phase Energy Meter with optional direct connection or CT connection

Voltage : AC 3x 220/380V

Current : AC 3 x 1(6)A AC,3 x 10(100) A AC

Accuracy : KWh Class 0.5%

Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, kvarh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options and Features : Auxiliary Function, Multi-Rate/Tariff, RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic

DC Multifunction Meter

TYPE: EM200DC

Description

Measure voltage, current, power, forward and reverse power in DC system

Event recording of switch (Modbus protocol), programming and event setting records, instantaneous and timing freeze function of data, maximum and minimum value recording function of voltage and current power

Voltage : DC 0-1000V

Current: Shunt:0-75mV, Hall sensor:0-20mA、4-20mA、0-5V,0-10V

Accuracy : KWh Class 1.0%

Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options and Features : DI/DO, Relay alarm output

RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic

DC Multifunction Meter

TYPE: EM201DC

Description

Event recording of switch (Modbus protocol), programming and event setting records, instantaneous and timing freeze function of data, maximum and minimum value recording function of voltage and current power

Input Voltage : 0~100V, 0~500V, 0~1000V

Power Supply : 85~265VAC/DC, 20~60VDC,100-350VDC

Current : Shunt:0-75mV, Hall sensor:0-20mA、4-20mA、0-5V,0-10V

Accuracy : KWh Class 1.0%

Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options and Features : DI/DO, Relay alarm output, RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic

AC Multifunction Meter

TYPE: EM400

Description

 Three Phase Multifunction Meter for

  • True RMS Measurements
  • Unbalance & Phase Angles
  • Demands and Multi-Tariff energy.
  • Max/Min Log with Timestamp
  • Alarms and SOE Logs
  • External Option module

Voltage : AC 100v, 110V, 220V, 400V, 690V

Current : 1A/5A CT

Auxiliary power supply : AC/DC 85V~265V or AC/DC 115~415V

Accuracy : Voltage, current and power:class 0.5S/0.2S/ Active power:class 0.5S/0.2S, Reactive power: class 2

Pulse output : Output mode: Optocoupler pulse with open collector; Pulse constant:4000(5A)、8000(1A) imp/kWh.

Consumption : Voltage: Power consumption:<0.5VA;
Current: Power consumption:< 0.5VA;
Auxiliary power supply: power consumption≤15VA

Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, kvarh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options and Features : Auxiliary Function, Multi-Rate/Tarriff, RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic

Multi-channel Meter

TYPE: EM201

Description

Three Phase Multi channel Energy Meter

Voltage : AC 3x 220/380V

Current : AC 3 x 1(6)A AC,3 x 10(80) A AC

Accuracy : KWh Class 0.5%

Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, kvarh, Power measurement (999999.99kWh)

Mounting : DIN 35mm

Options and Features : Auxiliary Function, Multi-Rate/Tarriff, RS485(Modbus RTU), Keypad Programming

Smart Gateway

Type: BGW10

BAS IoT Smart Gateway

Upstream Methods:

 4G LTE (Support Global Frequency Bands)

Wi-Fi (Supports 2.4G frequency band)

Ethernet (10/100M Adaptive)

DP( Profibus with address 1~125)

Upstream Protocol : MODBUS-TCP, MQTT

Downstream Methods :  RS485 Interface

Downstream Protocol :  MODBUS-RTU

Support : Up to 20~25 Acrel Devices with RS485 (MODBUS-RTU)

Power Supply : 24Vdc (default); 85~265Vac/Vdc (via AWT100-POW Module)

Standard&Certificate : CE-RED; IEC; LVD; EMC

Smart Gateway

Type: BGW20

Double wide voltage (DC / AC 85V ~ 265V) reverse connection protection

  • Support 2G/3G/4G
  • Support local and remote configuration maintenance and real-time data monitoring
  • 64 device data collection, support MODBUS-RTU or MODBUS-TCP device
  • Support breakpoint continuation, Json for data transmit
  • Support standard 8GB SD card (Max. 32GB)
  • Multiple alarm setting for each device

Power Monitoring and Protection

Type: BPR300

  • A complete set of protection, related to the application.
  • 5 current input, 3 voltage input, 11DI, 5DO.
  • Auxiliary power supply adapts with AC 220V, DC 220V, DC 110V, AC 110V, DC 48V, DC 24V;
  • 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU.
  • 1 GPS for GPS timing;
  • More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
  • Powerful graphic programmable Logic.

Power Monitoring and Protection

Type: BPR400

  • A complete set of protection, related to the application;
  • 4 current input, 4 voltage input, 12DI, 5DO;
  • Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V;
  • 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;
  • 1 RS232 for user update;
  • More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
  • Powerful graphic programmable Logic. 

Power Monitoring and Protection

Type: BPR400

  • A complete set of protection, related to the application;
  • 4 current input, 4 voltage input, 12DI, 5DO;
  • Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V;
  • 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;
  • 1 RS232 for user update;
  • More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
  • Powerful graphic programmable Logic. 

Real-Time Temperature Monitors

Type: BTMP10

  • Wireless temperature measurement, maximum measuring 60 points;
  • 4 digital inputs;
  • 2 alarm relays;
  • LCD display;
  • Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V;
  • 1 RS485 serial communication, Modbus-RTU.

Real-Time Temperature Monitors

Type: BTCP10

  • Wireless transmit, 433MHz;
  • Wireless transmission distance, 50 meters in open area;
  • Battery -powered, more than 5 years(25℃);
  • Widely temperature measuring range, -40℃~+125℃.

Power Quality Management

Type: BASAPF

  • 380V±15%,50Hz±2%
  • Full response time ≤ 5ms
  • 30A, 50A, 75A,100A or 150A
  • RS485(Modbus-RTU)or Ethernet(Modbus-TCP)
  • Frozen data
  • 2-51st Harmonic
  1. Flexible compensation method:Compensate for harmonics only, compensate for reactive power only, compensate for both harmonics and reactive power,could compensate for 2th-25th harmonics or compensate for specific harmonics.
  2. Ability of managing three-phase imbalance;
  3. Linear compensation,Response time ≤ 5ms;
  4. Humanized human-computer interaction interface, which displays real-time power quality information of the system and the ontology. This interface has the ability to control the device remotely and easy to operate;
  5. Adopt imported IGBT which has high power density and high reliability;
  6. Using DSP digital control system for high speed detection and calculation;
  7. With remote communication interface, real-time monitoring through PC;
  8. Standard modular design which reduces lead times and increases reliability and maintainability.

Power Quality Management

Type: BASSVG Static VAR Generator

  • 380V±15%,50Hz±2%
  • Full response time ≤ 5ms
  • 30kVA,50kVA,75kVA or 100kVA
  • RS485(Modbus-RTU)or Ethernet(Modbus-TCP)
  • Frozen data

1)Flexible compensation method:Compensating for reactive power from the load,filter out harmonics within 5th, 7th, 9th, 11th, and 13th;

2)Ability of managing three-phase imbalance;

3)Linear compensation,Response time ≤ 5ms;

4)Humanized human-computer interaction interface, which displays real-time power quality information of the system and the ontology. This interface has the ability to control the device remotely and easy to operate;

5)Adopt imported IGBT which has high power density and high reliability;

6)Using DSP digital control system for high speed detection and calculation;

7)With remote communication interface, real-time monitoring through PC;

8)Standard modular design which reduces lead times and increases reliability and maintainability.

Power Sensors

Type: BASHS

  • AC, DC, pulse and other complex current
  • Small package size
  • Low power consumption
  • Extended measuring range

Power Sensors

Type: BASCT-SC

  • Split core current transformer
  • Easy to install without power off.
  • Suitable for electricity renovation project
  • Rated Primary Current: 0-6000A
  • Rated Secondary Current: X/1A or X/5A

Power Sensors

Type: BASCT-OC

  • Split core current transformer
  • Easy to install without power off.
  • Suitable for electricity renovation project
  • Rated Primary Current: 0-6000A
  • Rated Secondary Current: X/1A or X/5A

Power Sensors

Type: BASCT-CC

  • Current transformer for measurement
  • Suitable for cables or copper bus
  • Used with energy meters or relays
  • Rated Primary Current: 0-6000A
  • Rated Secondary Current: X/1A or X/5A

Power Sensors

Type: BASCT-3C

  • Combined current transformer is also called the three-phase current transformer
  • As current signal acquisition device, it is generally matched with multi-loop current monitoring device (AMC16), PZ300, moulded case circuit breaker and other products.
  • It can save installation space, reduce the cumbersome wiring, be convenient to use and effectively reduce the cost.
  • Rated Primary Current: 0-6000A
  • Rated Secondary Current: X/1A or X/5A

Navigation

Contact Details

South Africa: +2776 219 8389
Zimbabwe: +263 772 219 9999

©2023. BAS Africa. All Rights Reserved

Design by Digital Aion Media Group

Scroll to Top