Our Products
Single Phase Meters
TYPE: EM101
Description
1P Single Phase Energy Meter capable of single total active energy measurement
Voltage : 1P AC154~264V(L-N)
Current : AC 10(60)A
Accuracy : KWh Class 1, Kvarh Class 2
Display : Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options : RS485(Modbus RTU)
Single Phase Meters
TYPE: EM102
Description
2P Single Phase Energy Meter capable of single total active energy measurement
Voltage : 1P AC154~264V(L-N)
Current : AC 10(60)A, 20(100) A
Accuracy : KWh Class 1, Kvarh Class 2
Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options and Features
RS485(Modbus RTU) , Pulse Output, Keypad Programming
Single Phase Meters
TYPE: EM103
Description
Single Phase 2-Wire Energy Meter capable of single total active energy measurement
Voltage : AC154~264V(L-N)
Current : AC 10(60)A, 20(100) A
Accuracy : KWh Class 1
Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options and Features : Multi-Rate/Tarriff, RS485(Modbus RTU), Pulse Output, Keypad Programming
Three Phase Meters
TYPE: EM200
Description
Three Phase Energy Meter with optional direct connection or CT connection
Voltage : AC100~120V or 380~456V (L-L)
Current : AC 1(6) A AC, 10(80) A AC
Accuracy : KWh Class 0.5%
Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options and Features : Auxiliary Function, Multi-Rate/Tarriff, RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic
Three Phase Meters
TYPE: EM201
Description
Three Phase Energy Meter with optional direct connection or CT connection
Voltage : AC 3x 220/380V
Current : AC 3 x 1(6)A AC,3 x 10(100) A AC
Accuracy : KWh Class 0.5%
Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, kvarh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options and Features : Auxiliary Function, Multi-Rate/Tariff, RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic
DC Multifunction Meter
TYPE: EM200DC
Description
Measure voltage, current, power, forward and reverse power in DC system
Event recording of switch (Modbus protocol), programming and event setting records, instantaneous and timing freeze function of data, maximum and minimum value recording function of voltage and current power
Voltage : DC 0-1000V
Current: Shunt:0-75mV, Hall sensor:0-20mA、4-20mA、0-5V,0-10V
Accuracy : KWh Class 1.0%
Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options and Features : DI/DO, Relay alarm output
RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic
DC Multifunction Meter
TYPE: EM201DC
Description
Event recording of switch (Modbus protocol), programming and event setting records, instantaneous and timing freeze function of data, maximum and minimum value recording function of voltage and current power
Input Voltage : 0~100V, 0~500V, 0~1000V
Power Supply : 85~265VAC/DC, 20~60VDC,100-350VDC
Current : Shunt:0-75mV, Hall sensor:0-20mA、4-20mA、0-5V,0-10V
Accuracy : KWh Class 1.0%
Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options and Features : DI/DO, Relay alarm output, RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic
AC Multifunction Meter
TYPE: EM400
Description
Three Phase Multifunction Meter for
- True RMS Measurements
- Unbalance & Phase Angles
- Demands and Multi-Tariff energy.
- Max/Min Log with Timestamp
- Alarms and SOE Logs
- External Option module
Voltage : AC 100v, 110V, 220V, 400V, 690V
Current : 1A/5A CT
Auxiliary power supply : AC/DC 85V~265V or AC/DC 115~415V
Accuracy : Voltage, current and power:class 0.5S/0.2S/ Active power:class 0.5S/0.2S, Reactive power: class 2
Pulse output : Output mode: Optocoupler pulse with open collector; Pulse constant:4000(5A)、8000(1A) imp/kWh.
Consumption : Voltage: Power consumption:<0.5VA;
Current: Power consumption:< 0.5VA;
Auxiliary power supply: power consumption≤15VA
Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, kvarh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options and Features : Auxiliary Function, Multi-Rate/Tarriff, RS485(Modbus RTU), Pulse Output, Keypad Programming, 2~31st & Total Harmonic
Multi-channel Meter
TYPE: EM201
Description
Three Phase Multi channel Energy Meter
Voltage : AC 3x 220/380V
Current : AC 3 x 1(6)A AC,3 x 10(80) A AC
Accuracy : KWh Class 0.5%
Display : 8 Digit LCD Display U, I, P, Q, PF, kWh, kvarh, Power measurement (999999.99kWh)
Mounting : DIN 35mm
Options and Features : Auxiliary Function, Multi-Rate/Tarriff, RS485(Modbus RTU), Keypad Programming
Smart Gateway
Type: BGW10
BAS IoT Smart Gateway
Upstream Methods:
4G LTE (Support Global Frequency Bands)
Wi-Fi (Supports 2.4G frequency band)
Ethernet (10/100M Adaptive)
DP( Profibus with address 1~125)
Upstream Protocol : MODBUS-TCP, MQTT
Downstream Methods : RS485 Interface
Downstream Protocol : MODBUS-RTU
Support : Up to 20~25 Acrel Devices with RS485 (MODBUS-RTU)
Power Supply : 24Vdc (default); 85~265Vac/Vdc (via AWT100-POW Module)
Standard&Certificate : CE-RED; IEC; LVD; EMC
Smart Gateway
Type: BGW20
Double wide voltage (DC / AC 85V ~ 265V) reverse connection protection
- Support 2G/3G/4G
- Support local and remote configuration maintenance and real-time data monitoring
- 64 device data collection, support MODBUS-RTU or MODBUS-TCP device
- Support breakpoint continuation, Json for data transmit
- Support standard 8GB SD card (Max. 32GB)
- Multiple alarm setting for each device
Power Monitoring and Protection
Type: BPR300
- A complete set of protection, related to the application.
- 5 current input, 3 voltage input, 11DI, 5DO.
- Auxiliary power supply adapts with AC 220V, DC 220V, DC 110V, AC 110V, DC 48V, DC 24V;
- 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU.
- 1 GPS for GPS timing;
- More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
- Powerful graphic programmable Logic.
Power Monitoring and Protection
Type: BPR400
- A complete set of protection, related to the application;
- 4 current input, 4 voltage input, 12DI, 5DO;
- Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V;
- 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;
- 1 RS232 for user update;
- More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
- Powerful graphic programmable Logic.
Power Monitoring and Protection
Type: BPR400
- A complete set of protection, related to the application;
- 4 current input, 4 voltage input, 12DI, 5DO;
- Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V;
- 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;
- 1 RS232 for user update;
- More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
- Powerful graphic programmable Logic.
Real-Time Temperature Monitors
Type: BTMP10
- Wireless temperature measurement, maximum measuring 60 points;
- 4 digital inputs;
- 2 alarm relays;
- LCD display;
- Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V;
- 1 RS485 serial communication, Modbus-RTU.
Real-Time Temperature Monitors
Type: BTCP10
- Wireless transmit, 433MHz;
- Wireless transmission distance, 50 meters in open area;
- Battery -powered, more than 5 years(25℃);
- Widely temperature measuring range, -40℃~+125℃.
Power Quality Management
Type: BASAPF
- 380V±15%,50Hz±2%
- Full response time ≤ 5ms
- 30A, 50A, 75A,100A or 150A
- RS485(Modbus-RTU)or Ethernet(Modbus-TCP)
- Frozen data
- 2-51st Harmonic
- Flexible compensation method:Compensate for harmonics only, compensate for reactive power only, compensate for both harmonics and reactive power,could compensate for 2th-25th harmonics or compensate for specific harmonics.
- Ability of managing three-phase imbalance;
- Linear compensation,Response time ≤ 5ms;
- Humanized human-computer interaction interface, which displays real-time power quality information of the system and the ontology. This interface has the ability to control the device remotely and easy to operate;
- Adopt imported IGBT which has high power density and high reliability;
- Using DSP digital control system for high speed detection and calculation;
- With remote communication interface, real-time monitoring through PC;
- Standard modular design which reduces lead times and increases reliability and maintainability.
Power Quality Management
Type: BASSVG Static VAR Generator
- 380V±15%,50Hz±2%
- Full response time ≤ 5ms
- 30kVA,50kVA,75kVA or 100kVA
- RS485(Modbus-RTU)or Ethernet(Modbus-TCP)
- Frozen data
1)Flexible compensation method:Compensating for reactive power from the load,filter out harmonics within 5th, 7th, 9th, 11th, and 13th;
2)Ability of managing three-phase imbalance;
3)Linear compensation,Response time ≤ 5ms;
4)Humanized human-computer interaction interface, which displays real-time power quality information of the system and the ontology. This interface has the ability to control the device remotely and easy to operate;
5)Adopt imported IGBT which has high power density and high reliability;
6)Using DSP digital control system for high speed detection and calculation;
7)With remote communication interface, real-time monitoring through PC;
8)Standard modular design which reduces lead times and increases reliability and maintainability.
Power Sensors
Type: BASHS
- AC, DC, pulse and other complex current
- Small package size
- Low power consumption
- Extended measuring range
Power Sensors
Type: BASCT-SC
- Split core current transformer
- Easy to install without power off.
- Suitable for electricity renovation project
- Rated Primary Current: 0-6000A
- Rated Secondary Current: X/1A or X/5A
Power Sensors
Type: BASCT-OC
- Split core current transformer
- Easy to install without power off.
- Suitable for electricity renovation project
- Rated Primary Current: 0-6000A
- Rated Secondary Current: X/1A or X/5A
Power Sensors
Type: BASCT-CC
- Current transformer for measurement
- Suitable for cables or copper bus
- Used with energy meters or relays
- Rated Primary Current: 0-6000A
- Rated Secondary Current: X/1A or X/5A
Power Sensors
Type: BASCT-3C
- Combined current transformer is also called the three-phase current transformer
- As current signal acquisition device, it is generally matched with multi-loop current monitoring device (AMC16), PZ300, moulded case circuit breaker and other products.
- It can save installation space, reduce the cumbersome wiring, be convenient to use and effectively reduce the cost.
- Rated Primary Current: 0-6000A
- Rated Secondary Current: X/1A or X/5A
Navigation
©2023. BAS Africa. All Rights Reserved
Design by Digital Aion Media Group